Test ID CYSPR Cyclosporine, Blood


Specimen Required


Container/Tube: Lavender top (EDTA)

Specimen Volume: 3 mL

Collection Instructions:

1. Collect specimen immediately before a scheduled dose.

2. Do not centrifuge.

3. Send whole blood specimen in original tube. Do not aliquot.

Additional Information: Therapeutic range applies to trough specimens collected immediately prior to a.m. dose.


Forms

If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

-Therapeutics Test Request (T831)

-Kidney Transplant Test Request

Secondary ID

35143

Useful For

Monitoring whole blood cyclosporine concentration during therapy, particularly in individuals coadministered cytochrome P450 (CYP) 3A4 substrates, inhibitors, or inducers

 

Adjusting dose to optimize immunosuppression while minimizing toxicity

 

Evaluating patient compliance

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Reporting Name

Cyclosporine, B

Specimen Type

Whole Blood EDTA

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time
Whole Blood EDTA Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK
Clotted specimens Reject

Reference Values

100-400 ng/mL (trough)

 

Target steady-state trough concentrations vary depending on the type of transplant, concomitant immunosuppression, clinical/institutional protocols, and time posttransplant. Results should be interpreted in conjunction with this clinical information and any physical signs/symptoms of rejection/toxicity.

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 day

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

80158

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CYSPR Cyclosporine, B 3520-4

 

Result ID Test Result Name Result LOINC Value
35143 Cyclosporine, B 3520-4